 Thyristor module TSM-LC10
Series/Type: TSM Ordering code: B44066T0010E402 Date: Version: November 2006 1
Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines, headers and footers. Please fill in the table and then change the colour to "White". This ensures that the table disappears for the customer pdf.
Identification/Classification 1: (header 1) Identification/Classification 2: (header 2) Ordering code: Series/Type: Preliminary data (optional): (if necessary) Department: Date: Thyristor module for dynamic PFC Accessories for power factor correction B44066T0010E402 Thyristor module TSM-LC10 Preliminary data FK PC PM PFC November 2006
(c) EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Thyristor module for dynamic PFC Accessories for power factor correction
Preliminary data
B44066T0010E402 Thyristor module TSM-LC10
Characteristics Fast electronically controlled self observing thyristor switch For capacitive loads up to 12.5 kvar Suitable for designing dynamic PFC-systems in 380 and 400 V grids Micro-processor controlled alignment to tuned or detuned capacitor branches (up to 14 %) for optimized switching behaviour No system perturbation due to switching operations (transients) Switching without delay Maintenance-free Long useful service life No noise emission during switching operation Compact module ready for connection No auxiliary voltage required
Features
* Easy installation * * Mounting position Display and control via LED display * Permanent self-monitoring Mechanical assembly directly on a mounting plate Self check after turn-on of main voltage Optimized switching behaviour to the connected load (tuned/detuned) via the internal processor Storage of optimized parameters for optimum switching behaviour Upright; minimum 100 mm space on top and below Operation Faults Activation Voltage Operating state
FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 6
November 2006
Thyristor module for dynamic PFC Accessories for power factor correction
Preliminary data
B44066T0010E402 Thyristor module TSM-LC10
Technical data
Dimensions Weight Rated voltage Maximum voltage - in conventional PFC-systems (without reactors) - in detuned PFC-systems (7 % detuning) - in detuned PFC-systems (14 % detuning) Frequency Switching capability 440 V 440 V (no upwards tolerance permitted) 400 V 50/60 Hz Nominal output 10 kvar at 400 V Max. 12.5 kvar at 400 V with ambient temperature <40 C Activation Switching time Reset time Display Power circuit Power dissipation Fuses (mandatory for protection of components) Ambient operating temperature at nominal load 10 ... 24 V DC (approx. 20 mA) via terminal clamp, internally electrically isolated Approx. 5 ms Depending on degree of detuning and dimension of discharge resistor 2 status LEDs per phase: operation/fault and triggering signal Direct connection 4 pole via terminal clamps (D = 6 mm2 resp. 4 mm2), connection from the bottom PD (in W) = 2.0 x I (in A); at 400 V/12.5 kvar approx. 35 W 3 x electronic fuse superfast" NH00 AC 690 V, characteristic gRL 12.5 kvar: 35 A (e.g. SIBA Art.No. 20.477.20-35) -10 C ... +55 C 162 x 150 x 75 mm (w x h x d) Approx. 1.75 kg 380 ... 400 V
FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 6
November 2006
Thyristor module for dynamic PFC Accessories for power factor correction
Preliminary data Connection diagram: three-phase load (standard)
B44066T0010E402 Thyristor module TSM-LC10
FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 6
November 2006
Thyristor module for dynamic PFC Accessories for power factor correction
Preliminary data Cautions and Warnings
B44066T0010E402 Thyristor module TSM-LC10
General * Thyristor modules TSM series may only be used for the purpose they have been designed for. * Thyristor modules TSM series may only be used in combination with appropriate pre-switched grid separator device. * Thyristor modules have to be projected in such a way that in case of any failure no uncontrolled high current and voltages may occur. * The devices in operation have to be protected against moisture and dust, sufficient cooling has to be assured. Attention Due to the switching principle of the thyristor module the power capacitors are permanently loaded to the peak value of the grid voltage (DC voltage) even when switched off. Therefore following rules have to be obeyed in any case: * For standard PFC-systems (without reactors) power capacitors of 440 V nominal voltage have to be used; for detuned systems PFC capacitors of 525 V nominal voltage have to be used. * Due to the high voltage (2 x peak value of nominal voltage) that occurs, the discharge resistors of the power capacitors have to be replaced by special types (accessory EW22). * In dynamic systems with TSM modules no fast discharge reactors may be used (reactor = DCwise short circuit). * For standard PFC-systems 2 current limiting reactors are mandatory per thyristor module (accessory BD100). * Thyristor modules in general have to be protected by superfast electronic fuses. Principles for dimensioning have to be considered. Fuses in the system have to be marked. * Due to the special switching, the PFC capacitors are fully loaded even when the particular step has been switched off. Protection against contact has to be guaranteed. Warning signals in the systems are required. * Even in switched off state no electrical isolation is achieved for electronic switches. Therefore parts of the systems may not be touched after switching off the complete system before the capacitors have been completely discharged.
FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES OR PHYSICAL INJURY.
U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual
version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.
FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 6
November 2006
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-JONES, Alu-X, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
FK PC PM PFC Page 6 of 6
November 2006


▲Up To Search▲   

 
Price & Availability of B44066T0050E402

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X